C&D LCT II-1700

Alpine Power Systems' experienced technical support & sales team is here to assist your needs:

C&D Technologies' Standby Power Division, an experienced manufacturer of round cells, introduces the LCT II-1700. This flooded battery incorporates proven and reliable floating epoxy post seal design and features solid copper posts to improve short duration (less that 5 hrs) rates up to 12% over comparable products. This combination makes the LCT II-1700 a superior, high quality, reliable long-life battery for today's standby applications.

Features and Benefits:

Reliability

  • Proprietary design results in 12% increase in performance in short duration (< 5 hrs), high rate applications
  • Unique Floating Epoxy Post Seal construction provides leak-free operation throughout the product life
  • 30% greater jar-to-cover seal area reduces leaks for trouble-free operation
  • Waterbath charging results in consistently formed plates for reliable performance out of the box (no cycling required in the field)
  • Proprietary expander enables stable and uniform float voltages (down to 2.17 Vpc), reducing the need to equalize
  • Suspended positive plate permits free growth without pressure on jar and cover

Safe Operation

  • Flame-retardant covers enhance battery plant safety with self-extinguishing properties LOI>32%, UL 94V-0
  • Low-evaporation, flame-arrester vent to extend watering intervals and prevent external sparks from reacting with the hydrogen inside the cell
  • NEBS approved battery systems (cells and racks) that meet telecom companies'
  • specifications
  • Narrow 17" (43.18 cm) depth racks available – NEBS qualified

Cost Savings

  • Transparent container allows visual inspection of plates
  • No requirement for periodic specific gravity readings
  • 50% reduction in the quantity of posts for reduced installation and maintenance costs
  • Double-hole, cross-drilled posts for plates parallel or perpendicular to the rack installation
  • Lead-plated solid copper posts for low maintenance; bolt-on connections require
  • minimal retorquing
  • Redundant connectors standard for continuous operation for increased up-time and maintainability

Additional Details

Technology

  • Lead Acid - Flooded

Manufacturer

Downloads & Documentation

See below for documentation relating to this product line that is available to download. To download this documentation, please click on the desired document you’d like to download and fill out the required form information fields. You will be able to view and download the documents upon completion of the download form.

  • C&D LCT II Brochure
  • C&D LCT II Manual
  • C&D Material Safety Data Sheet
  • C&D LCT II Rack Literature
TOP