C&D VLA Flooded Battery Racks

Alpine Power Systems' experienced technical support & sales team is here to assist your needs:

C&D Technologies offers a wide range of VLA battery rack solutions that assure that specific customer site requirements are met.

C&D VRLA Battery Racks

On this page:

C&D Technologies offers a wide range of VLA battery rack solutions that assure that specific customer site requirements are met. Whether space, ease of use, or code compliance is your biggest concern C&D has a rack solution that meets your needs. Alpine Power Systems is a platinum value-added solution provider for C&D Technologies.

  • Non-seismic & Earthquake Protected (EP1, EP2), IEEE-693

  • 1-Tier, 2-tier, 3-tier, 2-Step Configurations Available

  • Heavy Guage Steel Construction

  • Compatible with C&D D, DJ, DJU, J, K, and L / XT Cell Types

C&D RDB & RDC Rack Features & Benefits:

C&D Technologies RDB and RDC racks offer a variety of quality and value-added features. Most notably, both rack series take advantage of a “common-frame” design among the Standard, EP1, and EP2 series for all but the RDC 3 Tier EP2 rack. This allows the racks to be field upgradeable by simply installing additional bracing, while not having to remove any batteries! Additionally, the racks use a “C-Channel” frame cross-section that is more robust than competitive designs. The RDB EP racks are qualified to meet UBC 1994 Section 1630 seismic loading conditions. The RDC EP racks are qualified to IBC 2009 Section 1613. Other features, such as built-in grounding provisions, are listed below. 

RDB 693 racks are qualified to IEEE 693-2005. C&D strives to be the leader in supplying the best quality racks to support its highly regarded flooded product line. The RDB and RDC racks offer a range of quality features while maintaining a competitive price structure.

Standard Rack Features & Benefits:

  • 1-Tier, 2-Tier, 3-Tier, and 2-Step styles in Standard and Custom Lengths

  • Strut Rails with Flame Retardant Polyethylene Rail Covers, Provide Electrical Isolation

  • Rugged “C-Channel” Frame Design

  • Welded Steel Frames with an Acid Resistant, Electrostatically Applied Epoxy Powder Coat, Telephone Gray

  • Electrical Grounding Provisions Built into Base of Each Frame

  • Flame Retardant PVC Battery Spacers Included with EP Racks (L-Racks Only) Spacers for all Other Sizes are Open-Cell Styrene (Styrofoam). Optional flame-retardant foam spacers also available.

  • Rails Accommodate Clip Nuts for Bolt-on Accessories

  • Simplified Installation with Accessible Anchor Bolt Locations

  • Racks are Shipped Unassembled

Rack Seismic Options:

  • RDB EP Racks Qualified to Meet Maximum UBC 1994 Seismic Requirements, Section 1630, for Essential and Above Grade, Zones 1-4. RDB models can be upgraded to UBC 1997. Contact C&D for information.

  • RDC EP Racks are Qualified to Meet Maximum IBC 2009 Seismic Requirements, Section 1613, for Essential, Top of Building, Site Class D, up to SS=300%. Available For L/XT Cells only.

  • RDB 693 Racks are Qualified to Meet Maximum IEEE 693 2005 requirements are available for some models.

Optional Rack Features:

  • Third “Center” Support Rail (L-Series Only)

  • Field Upgradeable from STD to EP1 to EP2

C&D RDB Series Earthquake Protected (EP) Racks

C&D offers a complete line of steel standby battery racks for use in locations that are subject to seismic disturbances.  Two Earthquake Protected battery storage rack categories (EP1 and EP2) are offered to suit a variety of seismic loading conditions. These designs have been qualified to the 1994 Uniform Building Code (UBC), Chapter 16, Division III, “Earthquake Design”, Section 1630, “Lateral Force on Elements of Structures, Nonstructural Components and Equipment Supported by Structures.”

C&D RDB Rack Part Numbers:

RDB0700, RDB0701, RDB0702, RDB0703, RDB0800, RDB0801, RDB0802

RDB0803, RDB0800, RDB0801, RDB0802, RDB0803

C&D RDC Series Earthquake Protected (EP) Racks

C&D now offers a complete line of IBC 2009 certified stand-by battery racks, the RDC series, for the XT and L Series Batteries. Two Earthquake Protected battery storage rack categories (EP1 and EP2) are offered to suit a variety of seismic loading conditions. These designs have been qualified to the 2009 International Building Code (IBC), Chapter 16, “Structural Design”, Section 1613, “Earthquake Loads.” The qualification also covers the 2000, 2003, and 2006 versions of IBC as well as UBC 1994 and UBC 1997.

C&D RDC Rack Part Numbers:

RDC0900, RDC0901, RDC0902, RDC0903, RDC0900, RDC0901, RDC0902, RDC0903

C&D VLA Flooded Battery Rack Model Numbers:

700 Series, 701 Series, 702 Series, 703 Series, 800 Series, 801 Series, 802 Series, 803 Series, 900 Series, 901 Series, 902 Series, 903 Series

Alpine Power Systems provides critical power services on all C&D battery offerings. Alpine's certified technician's can provide C&D installation, preventative maintenance, monitoring and recycling services nationwide. Contact our call center today for quote requests and technical inquiries.

Applications

  • Enterprise Data Center
  • Colocation/Hosting

Manufacturer

C&D Technologies

C&D Technology Power Solutions

See below for documentation relating to this product line that is available to download. To download this documentation, please click on the desired document you’d like to download and fill out the required form information fields. You will be able to view and download the documents upon completion of the download form.

PDF Document
c-d-vla-flooded-battery-racks.pdf

Find C&D VLA Flooded Battery Racks in the following product categories:

ISO Certifications

Alpine Power Systems is proud to have three ISO Certifications that have been awarded to us after comprehensive audits completed by third-party, independent experts. Alpine must validate that all ISO processes are being followed through yearly follow up inspections.

Certification Certification Certification

Contact Us

Alpine Power Systems' experienced technical support & sales team are here to assist your needs.